Serial Number Rups 2000 Average ratng: 8,5/10 7200 votes
Rups 2000 download

Using the RUPS 2000 software from the supplied CD, I asked it to. Voltage indication, etc, but there is no no serial number, so it can not be. Which military standards does Acumentrics' RUPS hold? Cells replaced, please email the UPS model number and the serial number of the battery pack. The 2000 Watt Rugged-UPS™ product and its accessories are chemically resistant to.

For a list of user-reported dumps of NUT-supported devices, go visit the.

This driver supports hardware from many different manufacturers as it only uses the very simplest of signaling schemes. Contact closure refers to a kind of interface where basic high/low signals are provided to indicate status. This kind of UPS can only report line power and battery status. This means that you will only get the essentials in ups.status: OL, OB, and LB.

Anything else requires a smarter UPS. Cabling Cabling is different for every kind of UPS. See the table below for information on what is known to work with a given UPS type. Extra Arguments This driver supports the following settings in the (5): upstype= type Required. Configures the driver for a specific kind of UPS. See the UPS Types section below for more information on which entries are available.

Mfr= string Optional. The very nature of a generic UPS driver sometimes means that the stock manufacturer data has no relation to the actual hardware that is attached. With the mfr setting, you can change the value that is seen by clients that monitor this UPS.

Model= string Optional. This is like mfr above, but it overrides the model string instead. Serial= string Optional. This is like mfr above and intended to record the identification string of the UPS. It is titled 'serial' because usually this string is referred to as the serial number.

2000

Sdtime= value Optional. The driver will sleep for this many seconds after setting the shutdown signal. This is necessary for some hardware which requires a sustained level to activate the shutdown sequence. The default behavior of the driver is to exit immediately. If this doesn't reliably trigger a shutdown in your UPS hardware, use this setting to give it more time to react. Note very large values for sdtime may create warnings from upsdrvctl if it gets tired of waiting for the driver to return. Custom Configurations You may override the values for CP, OL, LB, and SD by defining them in the (5) after the upstype setting.

For example, to set the cable power to DTR and the low battery value to DCD, it would look like this: CP = DTR LB = DCD Recognized values for input lines are CTS, DCD, and RNG. Recognized values for output lines are DTR, RTS, and ST. Kameri See below for more about what these signals mean. These values may be negated for active low signals. That is, 'LB=-DCD' recognizes a low battery condition when DCD is not held high. Type Information The essence of a UPS definition in this driver is how it uses the serial lines that are available.

These are the abbreviations you will see below: OL On line (no power failure) (opposite of OB - on battery) LB Low battery SD Shutdown load CP Cable power (must be present for cable to have valid reading) CTS Clear to Send. Received from the UPS. RTS Ready to Send. Sent by the PC. DCD Data Carrier Detect. Received from the UPS.

Popular Posts

Rups 2000 download

Using the RUPS 2000 software from the supplied CD, I asked it to. Voltage indication, etc, but there is no no serial number, so it can not be. Which military standards does Acumentrics' RUPS hold? Cells replaced, please email the UPS model number and the serial number of the battery pack. The 2000 Watt Rugged-UPS™ product and its accessories are chemically resistant to.

For a list of user-reported dumps of NUT-supported devices, go visit the.

This driver supports hardware from many different manufacturers as it only uses the very simplest of signaling schemes. Contact closure refers to a kind of interface where basic high/low signals are provided to indicate status. This kind of UPS can only report line power and battery status. This means that you will only get the essentials in ups.status: OL, OB, and LB.

Anything else requires a smarter UPS. Cabling Cabling is different for every kind of UPS. See the table below for information on what is known to work with a given UPS type. Extra Arguments This driver supports the following settings in the (5): upstype= type Required. Configures the driver for a specific kind of UPS. See the UPS Types section below for more information on which entries are available.

Mfr= string Optional. The very nature of a generic UPS driver sometimes means that the stock manufacturer data has no relation to the actual hardware that is attached. With the mfr setting, you can change the value that is seen by clients that monitor this UPS.

Model= string Optional. This is like mfr above, but it overrides the model string instead. Serial= string Optional. This is like mfr above and intended to record the identification string of the UPS. It is titled 'serial' because usually this string is referred to as the serial number.

2000

Sdtime= value Optional. The driver will sleep for this many seconds after setting the shutdown signal. This is necessary for some hardware which requires a sustained level to activate the shutdown sequence. The default behavior of the driver is to exit immediately. If this doesn't reliably trigger a shutdown in your UPS hardware, use this setting to give it more time to react. Note very large values for sdtime may create warnings from upsdrvctl if it gets tired of waiting for the driver to return. Custom Configurations You may override the values for CP, OL, LB, and SD by defining them in the (5) after the upstype setting.

For example, to set the cable power to DTR and the low battery value to DCD, it would look like this: CP = DTR LB = DCD Recognized values for input lines are CTS, DCD, and RNG. Recognized values for output lines are DTR, RTS, and ST. Kameri See below for more about what these signals mean. These values may be negated for active low signals. That is, 'LB=-DCD' recognizes a low battery condition when DCD is not held high. Type Information The essence of a UPS definition in this driver is how it uses the serial lines that are available.

These are the abbreviations you will see below: OL On line (no power failure) (opposite of OB - on battery) LB Low battery SD Shutdown load CP Cable power (must be present for cable to have valid reading) CTS Clear to Send. Received from the UPS. RTS Ready to Send. Sent by the PC. DCD Data Carrier Detect. Received from the UPS.

..." style="letter-spacing:inherit;">Serial Number Rups 2000(27.02.2019)
  • Serial Number Rups 2000 Average ratng: 8,5/10 7200 votes
  • Rups 2000 download

    Using the RUPS 2000 software from the supplied CD, I asked it to. Voltage indication, etc, but there is no no serial number, so it can not be. Which military standards does Acumentrics' RUPS hold? Cells replaced, please email the UPS model number and the serial number of the battery pack. The 2000 Watt Rugged-UPS™ product and its accessories are chemically resistant to.

    For a list of user-reported dumps of NUT-supported devices, go visit the.

    This driver supports hardware from many different manufacturers as it only uses the very simplest of signaling schemes. Contact closure refers to a kind of interface where basic high/low signals are provided to indicate status. This kind of UPS can only report line power and battery status. This means that you will only get the essentials in ups.status: OL, OB, and LB.

    Anything else requires a smarter UPS. Cabling Cabling is different for every kind of UPS. See the table below for information on what is known to work with a given UPS type. Extra Arguments This driver supports the following settings in the (5): upstype= type Required. Configures the driver for a specific kind of UPS. See the UPS Types section below for more information on which entries are available.

    Mfr= string Optional. The very nature of a generic UPS driver sometimes means that the stock manufacturer data has no relation to the actual hardware that is attached. With the mfr setting, you can change the value that is seen by clients that monitor this UPS.

    Model= string Optional. This is like mfr above, but it overrides the model string instead. Serial= string Optional. This is like mfr above and intended to record the identification string of the UPS. It is titled 'serial' because usually this string is referred to as the serial number.

    2000

    Sdtime= value Optional. The driver will sleep for this many seconds after setting the shutdown signal. This is necessary for some hardware which requires a sustained level to activate the shutdown sequence. The default behavior of the driver is to exit immediately. If this doesn't reliably trigger a shutdown in your UPS hardware, use this setting to give it more time to react. Note very large values for sdtime may create warnings from upsdrvctl if it gets tired of waiting for the driver to return. Custom Configurations You may override the values for CP, OL, LB, and SD by defining them in the (5) after the upstype setting.

    For example, to set the cable power to DTR and the low battery value to DCD, it would look like this: CP = DTR LB = DCD Recognized values for input lines are CTS, DCD, and RNG. Recognized values for output lines are DTR, RTS, and ST. Kameri See below for more about what these signals mean. These values may be negated for active low signals. That is, 'LB=-DCD' recognizes a low battery condition when DCD is not held high. Type Information The essence of a UPS definition in this driver is how it uses the serial lines that are available.

    These are the abbreviations you will see below: OL On line (no power failure) (opposite of OB - on battery) LB Low battery SD Shutdown load CP Cable power (must be present for cable to have valid reading) CTS Clear to Send. Received from the UPS. RTS Ready to Send. Sent by the PC. DCD Data Carrier Detect. Received from the UPS.

    ...">Serial Number Rups 2000(27.02.2019)